Features of the - Victron Battery Protect 12/24V 65A

12/24V auto ranging 

The Battery Protect automatically detects system voltage 

Programming made easy 

The Battery Protect can be set to engage / disengage at several different voltages. The seven segment display will indicate which setting has been chosen. 

A special setting for Li-ion batteries 

In this mode the Battery Protect can be controlled by the VE.Bus BMS. Note: the Battery Protect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual. 

Ultra low current consumption 

This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. 

Over voltage protection 

To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V. 

Ignition proof 

No relays but MOSFET switches, and therefore no sparks. 

Delayed alarm output 

The alarm output is activated if the battery voltage drops below the pre-set disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. 

Delayed load disconnect and delayed reconnect 

The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the pre-set reconnect voltage.


PRODUCT CODE: BPR000065400

Sunshine Solar Limited
Your Cart
Your Cart: Empty

Need Help? 01508 488 188 - Mon-Fri 9AM - 5PM

Categories
Location
Home / Store / Victron Products / Victron Battery Protect 12/24V 65A

Newsletters Signup

Sign up to Our Newsletter to receive special offers

card Logos
© 2024 Sunshine Solar Limited, all rights reserved worldwide.
Kryptronic eCommerce, Copyright 1999-2024 Kryptronic, Inc. - https://kryptronic.com/ [0.064284 / 1.274345]