Victron Energy Battery Protect 12/24V 100A Victron Energy Battery Protect 12/24V 100A Default Manufacturer The BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. BPR000100400 BPR000100400 57.89 Sunshine Solar Limited

Victron Energy Battery Protect 12/24V 100A

Victron Energy Battery Protect 12/24V 100A

The BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.

Item Number:
BPR000100400
Your Price:
£57.89
Points:
12 Worth £0.60
Your Total:
Quantity:
Description

BatteryProtect BP-100 

Max. continuous load current* 100A 

Peak current (during 30 seconds) 600A 

Operating voltage range 6 35V 

Current consumption When on: 1,5 mA When off or low voltage shutdown: 0,6 mA 

Alarm output delay 12 seconds 

Maximum load on alarm output 50 mA (short circuit proof) 

Load disconnect delay 90 seconds (immediate if triggered by the VE.Bus BMS) 

Load reconnect delay 30 seconds 

Default thresholds Disengage: 10,5V or 21V Engage: 12V or 24V 

Operating temperature range Full load: -40C to +40C (up to 60% of nominal load at 50C) 

IP rating Electronics: IP67 (potted) 

Connections: IP00 Connection: M8 

Weight: 0,5 kg 

Dimensions (hxwxd) 59 x 42 x 115 mm



12/24V auto ranging 

The BatteryProtect automatically detects system voltage 

Programming made easy 

The BatteryProtect can be set to engage / disengage at several different voltages. The seven segment display will indicate which setting has been chosen. 

A special setting for Li-ion batteries 

In this mode the BatteryProtect can be controlled by the VE.Bus BMS. Note: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual. 

Ultra low current consumption 

This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. 

Over voltage protection 

To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V. 

Ignition proof 

No relays but MOSFET switches, and therefore no sparks. 

Delayed alarm output 

The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. 

Delayed load disconnect and delayed reconnect 

The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.


PRODUCT CODE: PIN122120400

Sunshine Solar Limited
Your Cart
Your Cart: Empty

Need Help? 01508 488 188 - Mon-Fri 9AM - 5PM

Categories
Location
Home / Accessories / Regulators/Controllers / Victron Energy Battery Protect 12/24V 100A

Newsletters Signup

Sign up to Our Newsletter to receive special offers

card Logos
© 2019 Sunshine Solar Limited, all rights reserved worldwide.
Software: Kryptronic eCommerce, Copyright 1999-2019 Kryptronic, Inc. Exec Time: 0.143474 Seconds Memory Usage: 1.325569 Megabytes
Kryptronic